H Series Layout
Physical
Model HS05
Miner Capacity 1 Unit M64 Series Miner
Cabinet Dimensions(W*D*H) 480mm*600mm*545mm(1.57*1.97*1.79)
Net Wight 35 Kg Operation Weight 52 Kg
Electrical
Typ. Power Consumption 6 kW (Max. with Miner)
Voltage and Frequency 1Ph+ground 200V-240V 50/60Hz
Fluid
Coolant Deionized/Distilled water + Corrosion inhibitor
+Antifreeze (Based on site requirements)
Flow > 5L/min
Fluid Volume 3L (With Miner)
Heating
Inlet Water Temp. Range 35°C~70°C(Miner)/10°C~45°C(Heat exchanger)
Rated Heating Capacity 5 kW (17060 BTU/h)
Environment Conditions - Operating
Ambient Temperature Ran 0°c -40°C
2×Miner Slot(2U)
-
Whatsminer M33/M53/M63 Series
Dual Heat Supply Interface
-
Domestic Water Heating-Open Loop Floor
-
Radiator Heating-Close Loop
Build-In CDU
-
Silent Pump
-
Temperature & Pressure Sensors
-
Auto Filling System-Filling Pump and Water Tank
4.3 Inch Touch Screen
-
One-Button Start
-
System Failure Alarm
-
Operating Trend Curve
PLC Control
-
Industrial Grade Controller
-
PID Control Logic
Physical
Model HS20
Miner Capacity 2 Units
Cabinet Dimensions(W*D*H) 600mm*970mm*900mm
Wight 150kg(Net) / 205kg(Full Load)
Electrical
Max. Power Consumption 20 kW
Input Voltage & Frequency 3Phase 380-480V 50/60Hz
Fluid(Miner)
Water Capacity 15L
Inlet/Outlet Temperature 40°C/55°C @High Performance Mode Flow Rate 1.2m3/h
Operating Pressure <4bar
Coolant Pure water/distilled water + special corrosion inhibitor + antifreeze
(select the ratio according to the freezing point)
Fluid(Heating)
Heating Capacity 20kW (68000 BTU/h)
Inlet/Outlet Temperature 35°C/50°C @High Performance Mode
Flow Rate 1.2m3/h
Pressure Drop 40kPa @1.2m3/h
Pipe Connection G3/4 External Thread
Note: Customizable Design According to Specific Requirements
10×Miner Slot(2U)
-
Whatsminer M33/M53/M63 Series
PLC Control
-
Industrial Grade Controller
-
PID Control Logic
Build-In CDU
-
Variable Frequency Pump
-
Temperature & Pressure Sensors
-
Auto Filling System-Filling Pump and Water Tank
7 Inch Touch Screen
-
One-Button Start
-
System Failure Alarm
-
Operating Trend Curve
Build-In PDU
-
Main Circuit Breaker
-
Circuit Breaker Protection for Each Miner
-
Smart Electricity Meter
Physical
Model MS100
Miner Capacity 10 Units
Cabinet Dimensions(W*D*H) 800mm*1000mm*2050mm
Wight 350kg(Net) / 625kg(Full Load)
Electrical
Max. Power Consumption 100 kW
Input Voltage & Frequency 3Phase 380-480V 50/60Hz
Fluid(Miner)
Water Capacity 50L
Inlet/Outlet Temperature 40°C/55°C @High Performance Mode Flow Rate 6m3/h
Operating Pressure <4bar
Coolant Pure water/distilled water + special corrosion inhibitor + antifreeze
(select the ratio according to the freezing point)
Fluid(Heating)
Heating Capacity 100kW (340000 BTU/h)
Inlet/Outlet Temperature 35°C/50°C @High Performance Mode
Flow Rate 6m3/h
Pressure Drop 70kPa @1.2m3/h
Pipe Connection 1.5”Weld Ferrule (ISO 2852)
Note: Customizable Design According to Specific Requirements
20×Miner Slot(2U)
-
Whatsminer M33/M53/M63 Series
Build-In PDU
-
Main Circuit Breaker
-
Circuit Breaker Protection for Each Miner
-
Smart Electricity Meter
Build-In Network System
-
24×Port 100M Network Switcht
-
Pre-Connected Network Cable
Manifold
-
High Temperature and Aging Resistant Hose
-
Leak-Free Quick Connector
-
Automatic Air Exhaust System
Physical
Model NS200
Miner Capacity 20 Units
Cabinet Dimensions(W*D*H) 800mm*1000mm*2050mm
Wight 290kg(Net) / 890kg(Full Load)
Electrical
Max. Power Consumption 200 kW
Network 24 Ports 100M Network Switch
Input Voltage & Frequency 3Phase 380-480V 50/60Hz
Fluid(Miner)
Water Capacity 30L
Inlet/Outlet Temperature 40°C/55°C @High Performance Mode Flow Rate 12m3/h
Operating Pressure <4bar
Coolant Pure water/distilled water + special corrosion inhibitor + antifreeze
(select the ratio according to the freezing point)
Note: Customizable Design According to Specific Requirements