top of page

SCS/Dry Cooler

- Get more details -

Smart Control Systerm/ Dry Cooler

X series is our container product. We design it for fast deployment and easy installation and maintenance. It could adapt to a variety of complex, terrible outdoor environments. Highly compact design could let you save 30% space.

SCS Types

SCS200 l SCS400

12-24 m3 /h

image.png

SCS600 | SCS800 | SCS1000

36-60 m3 /h

image.png

SCS2000

120m3 /h

image.png

Physical

Model                                    SCS200                      SCS400                     SCS600                      SCS800                      SCS1000                      SCS2000
Miner Capacity                      20 Units                      40 Units                      60 Units                      80 Units                      100 Units                      200 Units
Dimensions(L*W*H)              800*1000*2050mm     800*100*2050mm       120
0*1000*2050mm   1200*1000*2050mm    1200*1000*2050mm    1400*1000*2050mm
Net Wight                               240kg/260kg              290kg/330kg                460kg/520kg             480kg/560kg                500kg/600kg              800kg/1000kg
Noise Level at 3m                                                     

Electrical

Typ. Power Consumption                                 6 kW (Max. with Miner)
Voltage and Frequency                                   1Ph+ground 200V-240V 50/60Hz

Fluid (Miner)

Water Capacity
Inlet/Outlet Temperature

Flow Rate
Operating Pressure
Coolant

Cooling System Solution-Dry Cooler(20-2000kW) Product Components

image.png

Dry Cooler SPECIFICATION

DC20 l DC100

Horizontal/Vertical

1*Fan

DC200 | DC400 

V-Shape Single-Row

2-4*Fan

DC600-DC1600

V-Shape Double-Row

6-18*Fan

Physical

Model                                                           HS05

Miner Capacity                                             1 Unit M64 Series Miner

Cabinet Dimensions(W*D*H)                       480mm*600mm*545mm(1.57*1.97*1.79)

Net Wight                                                     35 Kg                                                      Operation Weight                                         52 Kg                                   

Electrical

Typ. Power Consumption                                 6 kW (Max. with Miner)
Voltage and Frequency                                   1Ph+ground 200V-240V 50/60Hz

Fluid

Coolant                                                 Deionized/Distilled water + Corrosion inhibitor

                                                              +Antifreeze (Based on site requirements)
Flow                                                       > 5L/min
Fluid Volume                                         3L (With Miner)

Heating

Inlet Water Temp. Range                     35°C~70°C(Miner)/10°C~45°C(Heat exchanger)
Rated Heating Capacity                       5 kW (17060 BTU/h)

Environment Conditions - Operating

Ambient Temperature Ran                            0°c -40°C

bottom of page